Schluter® REPAIR KIT FOR DITRA-HEAT-E-HK HEATING CABLES
This is the official repair kit for DITRA-HEAT-E-HK heating cables — the fix for a cable that's been accidentally nicked, cut, or damaged during installation. If you've severed a heating cable with a trowel or utility knife (it happens more than anyone admits), this kit lets you splice it back together without replacing the entire cable.
Important: this kit is for repairs during installation, BEFORE the cable is covered with mortar and tile. If a cable fails after the floor is tiled, the repair process is significantly more involved (you'll need to locate the break and expose it). This kit provides the splice components — the access is up to you.
What's in the kit
- Heat-shrink splice connectors
- Connection hardware for rejoining the severed conductors
- Step-by-step splice instructions
When you need it
- Cable cut or nicked during installation (trowel, knife, or screw)
- Cable damaged during membrane placement
- Factory splice (cold lead junction) damaged during rough-in
- NOT for: Shortening a cable that's too long — cables CANNOT be cut to length. You must use the correct cable size for your heated area.
Important rules
- Test cable resistance with a multimeter BEFORE AND AFTER the repair — readings should match the factory specs on the cable label
- If resistance readings are significantly off after repair, the splice may not be reliable
- A properly spliced cable should match its original resistance within ±5%
- Document the repair — write the post-repair resistance on the cable box label
- This repair must be performed by a qualified person — incorrect splicing creates fire risk
Prevention tips
- Always test cable continuity at three points: before installation, after routing through membrane, after tiling
- Use caution when spreading mortar over routed cables — flat side of trowel, light pressure
- Mark cable locations on the membrane with tape before mortaring
- Keep a repair kit on-site for every DITRA-HEAT job — they're cheap insurance
Pairs with
- All DITRA-HEAT-E-HK heating cables (120V and 240V)
- A multimeter (not included — essential for testing)